Acta Geodaetica et Cartographica Sinica ›› 2023, Vol. 52 ›› Issue (1): 15-21.doi: 10.11947/j.AGCS.2023.20220347

• Express Paper • Previous Articles     Next Articles

High-precision on-orbit geometric calibration of the GF-14 satellite dual-line-array cameras

LU Xueliang1,2, WANG Jianrong1,2, YANG Xiuce1,2, LV Yuan1,2, HU Yan1,2, WEI Yongqiang1,2, CAO Bincai1,2   

  1. 1. State Key Laboratory of Geo-information Engineering, Xi'an 710054, China;
    2. Xi'an Research Institute of Survey and Mapping, Xi'an 710054, China
  • Received:2022-05-31 Revised:2022-09-05 Published:2023-02-09

Abstract: On-orbit geometric calibration is a key link for satellites to achieve high-precision positioning. In this paper, based on the 1∶2000 digital calibration test field in Ningxia, the calibration parameters of the dual-line-array cameras are calculated as a whole by the alternate iteration of forward intersection and backward intersection, and the high-precision on-orbit geometric calibration of the dual-line-array cameras of the GF-14 satellite is achieved. The calibration results were tested by using many testing fields around the world. The test results show that after high-precision geometric calibration, the accuracy of the direct forward intersection of the GF-14 satellite image can reach 2.34 m in plane and 1.97 m in elevation without ground control.

Key words: on-orbit geometric calibration, calibration test field, location accuracy without ground control points, GF-14 satellite