测绘学报 ›› 2016, Vol. 45 ›› Issue (5): 601-607.doi: 10.11947/j.AGCS.2016.20140539

• 摄影测量学与遥感 • 上一篇    下一篇

非量测数字相机实验室几何标定

袁枫1, 张继贤2, 齐维君1,2, 方爱平1,2   

  1. 1. 国家光电测距仪检测中心, 北京 100039;
    2. 中国测绘科学研究院, 北京 100830
  • 收稿日期:2014-11-13 修回日期:2016-02-03 出版日期:2016-05-20 发布日期:2016-05-30
  • 作者简介:袁枫(1981-),男,博士,主要研究方向为数字摄影测量、机载。E-mail: yf8426@126.com
  • 基金资助:
    测绘地理信息公益性行业科研专项(201512010);中国测绘科学研究院专项基金(7771531)

Laboratory Geometric Calibration of Non-metric Digital Camera

YUAN Feng1, ZHANG Jixian2, QI Weijun1,2, FANG Aiping1,2   

  1. 1. National Calibration Center for Electro-optical Distance Meter, Beijing 100039, China;
    2. Chinese Academy of Surveying and Mapping, Beijing 100830, ChinaAbstract
  • Received:2014-11-13 Revised:2016-02-03 Online:2016-05-20 Published:2016-05-30
  • Supported by:
    Public Science Research Program of Surveying, Mapping and Geoinformation (No. 201512010);Chinese Academy of Surveying and Mapping Special Fund (No. 7771531)

摘要: 非量测数字相机的几何标定,包括内方位元素和畸变的精确测定,直接影响其用于航空摄影测量的最终精度。本文研制出一套非量测数字相机实验室几何标定系统。该系统采用平行光管加星点板作为目标发生器,在测量出一组目标点在相机的CCD靶面上的像点坐标及对应的平行光线的入射角后,结合几何标定的数学模型,可以实现相机的高精度几何标定。采用佳能EOS 5D Mark Ⅱ和哈苏H3D两款典型的数字相机进行了试验与分析。试验结果验证了本文标定方法的正确性以及精度的可靠性。

关键词: 非量测数字相机, 几何标定, 内方位元素, 畸变

Abstract: Geometric calibration of non-metric digital camera, including the accurate determination of interior orientation elements and distortion parameters, directly affects the ultimate accuracy of its using in aerial photogrammetry. In this paper, a laboratory geometric calibration system of non-metric digital camera is developed. A collimator and a star tester are used as the target generator in this system. After measuring locations of targets in CCD and corresponding angles of parallel lights, high precision geometric calibration can be accomplished. Two kinds of mainstream digital aerial cameras, Canon EOS 5D Mark Ⅱ and Hasselblad H3D, are used to take experiments based on this system and the results are analyzed. Experiment results show that the method of this paper is correct and the calibration precision is reliable.

Key words: non-metric digital camera, geometric calibration, interior orientation elements, distortion

中图分类号: